3. Setting force adjustment
Value defined for each FLUSHFIX® part number (see FLUSHFIX® data sheet). To achieve this setting force, it is necessary to adjust the crimping tool air pressure. To adjust this parameter, the positioning of a regulator upstream of the crimping tool is recommended. The necessary air pressure may vary, depending on the crimping tool used. To define the right pressure, please refer to the table below.
For installation tooling distributed by LA CLUSIENNE-CLUFIX
| Fastening Tool |
Crimping pressure P (bars) |
| TFS102 / AP70304 |
P = F / 450 |
| TFS103 |
P = F / 185 |
| TFS104 |
P = F / 400 |
F: data available in the data sheet for the selected FLUSHFIX® part number
For all other installation tooling, please refer to the manufacturer's manual for the pressure / force ratio, or request LA CLUSIENNE-CLUFIX support. |