FLUSHFIX
Informazioni prodotto
Specifiche tecniche
Installation
Performances
Codifica
Su misura
Guida alla scelta
 
Technical data / Installation

< Metal sheet preparation - Tooling - Installation - Setting >

Metal sheet preparation

forme du trou M 6 M 8 M 10
CLUFIX Trou Cylindrique 9.0 11.0 13.0
dimensions: mm (tolerance provided in the data sheets)

Achievement process

Drilling
Laser cutting
Water jet cutting
Punching (for flat workpiece only)

 

< Metal sheet preparation - Tooling - Installation - Setting >

Installation tools

FLUSHFIX® should be fitted using LA CLUSIENNE-CLUFIX oleopneumatic crimping tools. Use of a specific anvil matching the selected FLUSHFIX® diameter is imperative.

FLUSHFIX Installation Tools
Crimping tool + tie-rod Anvil FLUSHFIX®

FLUSHFIX® installation process

FLUSHFIX Installation Process

< Metal sheet preparation - Tooling - Installation - Setting >

FLUSHFIX® installation settings

In order to guarantee optimal FLUSHFIX® installation, three key parameters must be taken into consideration:

1. Tie-rod adjustment
1.1 Screw FLUSHFIX® onto the tie-rod so that all the FLUSHFIX® threads are in contact with the shank (move the anvil, if necessary).
1.2 Place in the anvil in contact with the FLUSHFIX® head, then block the anvil in this position.

2. Stroke adjustment
Crimping tool stroke (S) on the installation tool must be set to maximum (at least 6 mm).

FLUSHFIX Stroke Adjustment

FLUSHFIX Stroke S

FLUSHFIX Stroke S

3. Setting force adjustment
Value defined for each FLUSHFIX® part number (see FLUSHFIX® data sheet). To achieve this setting force, it is necessary to adjust the crimping tool air pressure. To adjust this parameter, the positioning of a regulator upstream of the crimping tool is recommended. The necessary air pressure may vary, depending on the crimping tool used. To define the right pressure, please refer to the table below.

For installation tooling distributed by LA CLUSIENNE-CLUFIX
Fastening Tool Crimping pressure P (bars)
TFS102 / AP70304 P = F / 450
TFS103 P = F / 185
TFS104 P = F / 400
F: data available in the data sheet for the selected FLUSHFIX® part number
For all other installation tooling, please refer to the manufacturer's manual for the pressure / force ratio, or request LA CLUSIENNE-CLUFIX support.

< Metal sheet preparation - Tooling - Installation - Setting >

Setting force

Setting force data is given in the data sheets as a guideline only, and must be adjusted for particular customer applications.